Sign In | Join Free | My himfr.com
Home > Toxic Gas Detector >

O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process

Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process from wholesalers
     
    Buy cheap O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process from wholesalers
    • Buy cheap O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process from wholesalers
    • Buy cheap O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process from wholesalers
    • Buy cheap O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process from wholesalers

    O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process

    Ask Lasest Price
    Brand Name : YuanTe
    Model Number : YT-98H
    Certification : SIL CE ATEX IECEX ISO9001-2015
    Price : Negotiable
    Payment Terms : T/T, Western Union, Credit Card
    Supply Ability : 500PCS/DAY
    Delivery Time : 2-3 days
    • Product Details
    • Company Profile

    O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process


    Monitoring O3 Ozone Disinfection Process O3 Leakage Fix Wall Mount Toxic Gas Detector


    YT-98H-WH / YT-98H-WH-A series is a built-in pump-suction single & multi gas detector, which can detect 1-6 kinds of gases simultaneously and continously. With IECEx, ATEX certificate (on-going) and non-contact magnetic wand design, it can be installed and operated in explosion proof areas in Oil & Gas industry. In addition to 3-wire 4-20mA output with relay, it also offers Modbus protocols, making it compatible with most control systems. With optional wireless function, operator can view data on laptop, mobile phone or cloud system remotely.


    PID O3 Sensor Monitoring advantage:


    • With internal suction pump, fast response
    • Up to 6 kinds of gases can be detected at the same time. In complex and multi-gas environments, multiple installations can be reduced, saving time and effort.
    • 2.4-inch industrial-grade high-definition color screen with a resolution of 320*240 and a wide viewing angle of 120 degrees.
    • With wireless module, data can be uploaded to the cloud platform, environmental protection bureau or other
    • Platforms, providing SMS reminder function, the transmission signal is not limited by distance, and can be viewed in real time on mobile phones and computers. (optional)
    • With full software automatic verification function and zero calibration function, making gas monitoring more accurate and more reliable.
    • Standard 4-20mA current signal, RS485 modbus signal, 1 set of relay signal output
    • Standard infrared remote control, which can remotely control the detector and modify the detector settings.
    • With sound and light alarm function, there is sound and light alarm when reaching the alarm point. (optional)

    O3 Sensor Monitoring​ Specification


    Sampling methodBuilt in pump
    Pump flow rate0.35-0.5 L/Min

    Gas detected

    Ozone(O3),VOC, Oxygen(O2), Combustible gases(EX/LEL), Carbon monoxide(CO), Hydrogen sulfide(H2S), according to customer's requirements

    Detection principle

    PID 10.6eV, 11.7eV, Catalytic combustion/Infrared Ray(LEL), Electrochemistry(O2 CO H2S), sensor and ic are imported from UK, fast response and high precision

    Install method

    Wall-mounted, piping type, flow-type (according to the detected environment)

    Measure range

    O3:0-1ppm, 0-10/20/50/100ppm, 0-10000ppm

    VOC: 0-1ppm, 0-3ppm, 0-10ppm, 0-100ppm, 0-500ppm, 0-1000ppm, 0-10000ppm

    O2: 0-30%VOL/0-25%VOL

    EX: 0-100%LEL/0-100%VOL

    CO: 0-500ppm/0-1000PPM/0-2000ppm

    H2S: 0-100ppm/0-200PPM

    (Measure range is optional)

    Resolution

    O3: 0.01ppm, 0.1ppm

    VOC: 0.001ppm, 0.01ppm, 0.1ppm, 1ppm

    O2: 0.01%VOL

    EX: 1%LEL/0.01%VOL

    CO: 0.1ppm/1PPM/1ppm

    H2S: 0.01ppm/0.1PPM

    Precision

    ≤± 2% FS

    Signal output

    4-20mA, RS485, 1 set of relay output; 1-5VDC(optional), 2 sets of relay output(optional)

    Response time

    ≤10S

    Recovery time

    ≤10S

    Repeatability

    ≤±1%

    Linearity error

    ≤±1%

    Zero shift

    ≤±1%(FS/year)

    Display

    High-light nixie tube display

    Connection mode

    G1/2 external thread explosion-proof flexible pipe

    Unit

    ppm, mg/m3, g/m3, %LEL, %VOL

    Temperature

    -20 to 50°C

    Humidity

    0-95%RH

    Explosion-proof

    Ex d IIC T6 Gb

    Degree of protection

    IP65

    Alarm

    Sound, light

    Operating time

    24H

    Dimensions

    286*202*96mm (H x W x D)

    Weight

    3.4kg (3.8kg with alarm light)




    FAQ
    Fast Response Fixed Cocl2 Carbonyl Chloride Phosgene 0-1ppm Range Gas Leak Detector

    Fast Response Fixed Cocl2 Carbonyl Chloride Phosgene 0-1ppm Range Gas Leak Detector


    Quality O3 Ozone Leakage Fix Wall Mount Toxic Gas Detector Monitoring Disinfection Process for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen YuanTe Technology Co., Ltd. (Safegas)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)