Sign In | Join Free | My himfr.com
Home > Single Gas Detector >

Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector

Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector from wholesalers
     
    Buy cheap Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector from wholesalers
    • Buy cheap Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector from wholesalers

    Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector

    Ask Lasest Price
    Brand Name : YuanTe
    Model Number : SKY2000
    Certification : CNEX,ISO9001,CE
    Price : Negotiable
    Payment Terms : Western Union, T/T
    Supply Ability : 100 pieces/week
    Delivery Time : 3-5 working days
    • Product Details
    • Company Profile

    Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector

    Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector​


    SKY2000 series gas detector is a kind of fast response and high accuracy gas measurement device. With internal sampling pump, fast sampling speed and high flow rate, ensuring the response time of the detector. Unique design, small size and easy to carry with. Special high intensity engineering plastics housing, suitable for different kinds of situation and environment. We dedicate to provide you the most reliable, accurate and the safest solution of gas detection.


    Gas DetectedHfc125 Gas R125 R134A R404A
    Detection principleIR
    Sampling MethodPumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
    Measure Range0-2000ppm
    Resolution0.001ppm
    Precision≤± 2% F.S.
    Signal OutputHigh-speed data transmission by USB, available for data downloading and printing(optional function)
    Response Time≤10SRecovery Time≤10S
    Repeatability≤±1%Linearity error≤±1%
    Zero shift≤±1%(F.S/year)DisplayLCD dot matrix display
    Operating languageChinese/EnglishGas unitUnits are switchable
    Temperature-40~70Humidity0-95%RH
    Explosion-ProofExiaCT4Degree of protectionIP66
    Alarm modeSound, light, vibrationOperating time100h(pump off)
    Dimensions205*75*32mmWeight300g

    Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector

    Product Advantegas

    • Employing original imported first-class brand sensor.
    • (optional) High speed data transmission by USB, which can download and print data.
    • LCD dot matrix display, the gas type, unit, concentration, local time can be showed on the screen.
    • Support Chinese and English operation, easy to shift.
    • The gas concentration unit PPM and mg/m3 can be shifted quickly.
    • Built-in micro sampling pump, 10 grades of suction are available.
    • Explosion-proof certification, explosion-proof grade: Ex ia IIC T4 Ga

    Attentions
    ● The air intake of the sensor must be kept clean. Blocking the sensor's air intake may result in readings that are lower than the actual gas concentration or even the gas concentration. It is strictly forbidden to use compressed air to clean the air inlet of the sensor to avoid damage to the sensor.
    ● Catalytic Principle Flammable Gas Sensor and Infrared Principle Sensor can only accurately monitor designated gases. It should be noted, however, that the catalytic principle flammable sensor is not specific to a particular gas and will be able to react to other flammable gases.
    ● If the instrument is subject to physical impact or high pollution, the calibration cycle needs to be shortened.
    ● The sensitivity of flammable gas sensors will be affected by high concentrations of sulfides, halogen compounds, silicon-containing compounds, and gases containing "mercury" and "lead", steam, and high temperature organic acid gases. Avoid using them in environments containing the above chemicals. The instrument, if necessary, must be tested and calibrated after use to avoid affecting the accuracy of the instrument.

    ● The instrument is strictly prohibited from being used in a high concentration of flammable gas for a long time to avoid damage to the flammable sensor. If it is necessary, the instrument should be tested and calibrated after use to avoid affecting the accuracy of the instrument. If the flammable sensor is damaged, it needs to be replaced with a new one.


    FAQ

    Q1. How can I get the sample to check your quality?

    After price confirmation, you can require for samples to check our product’s quality.

    Q2. What can I get the price?

    We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please just call us we will regard your inquiry priority.

    Q3. What is your term of delivery?

    We accept EXW, DAP, FOB Shenzhen. You can choose the best convenient or cost effective way for you.

    Q4. What about the lead time for the mass production?

    Honestly, it depends on the order quantity and the season you place the order.

    Quality Refrigerant Gas Leak Detector Hfc125 Gas R125 R134A R404A Sensor IR Principle High Sensitivity Gas Detector for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen YuanTe Technology Co., Ltd. (Safegas)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)