Sign In | Join Free | My himfr.com
Home > Single Gas Detector >

Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

Shenzhen YuanTe Technology Co., Ltd. (Safegas)
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room from wholesalers
     
    Buy cheap Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room from wholesalers
    • Buy cheap Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room from wholesalers

    Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room

    Ask Lasest Price
    Brand Name : YuanTe
    Model Number : YT-96H
    Certification : CE ISO9001-2015
    Price : Negotiable
    Payment Terms : T/T, Western Union, Credit Card
    Supply Ability : 500PCS/DAY
    Delivery Time : 2-3 days
    • Product Details
    • Company Profile

    Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room


    Ozone PPB Level Meter For Safe High Precision UK Sensor Ozone Alarm Tester


    Product overview


    YT-96H-WH is specially designed for disinfection field like medicine clean room. It’s an online monitoring fixed ozone detector. Using imported brand electrochemical principle sensor, it’s small and light, fast response, accurate detection, reliable operation and convenient for maintenance. 24V DC power supply, standard 4-20mA, RS485 signal and a set of relay signal output. It’s non-explosion-proof design, so need to be installed in non-explosion-proof workplaces.
    Product Advantages
    All use imported brand electrochemical principle sensors
    Standard three-wire 4-20mA analog signal, RS485 signal output
    Compatible with various control panels, PLC, DCS and other control systems, can realize remote monitoring
    A set of relay signals is standard equipped, and can control peripheral sound and light alarms, fans, solenoid valves and other equipment
    Setting, calibration and remote monitoring can be realized by the upper software.

    Ozone PPB level Meter Specification


    Detected gas:
    Ozone, etc, according to customer's requirements.
    Detection principle:
    Electrochemical
    Measure range:
    0-1000ppb, 0-1ppm, 0-5ppm, 0-10ppm, 0-20ppm, 0-50ppm, 0-100ppm, etc, according to customer's requirements.
    Resolution:
    1ppb, 0.001ppm, 0.01ppm, 0.1ppm, 1ppm, etc, according to sensor and measure ranges.
    Accuracy:
    ≤±1-2%F.S.
    Response time:
    ≤30 seconds (T90)
    Display:
    Segment LCD
    Shell material:
    Flame Retardant Thermoplastic PS
    Concentration unit:
    ppm, mg/m3
    Alarm mode(Optional):
    Buzzer and light, high and low alarm values can be set by customer.
    Signal output:
    4-20mA, RS485, 1 set of relay output; 1-5VDC(optional)
    Communication and data download:
    With PC software, history data can be downloaded, stored, printed, and analyzed in computer (optional)
    Installation method:
    Wall-mounted
    Power supply:
    24VDC
    Language:
    English
    Humidity:
    0~95%RH (non-condensing)
    Temperature:
    -20℃~+50℃
    Working pressure:
    91~111kpa
    Size:
    80.2*145*62.2mm
    Weight:
    230g (without packaging)



    Accessories & Configuration list
    Standard accessories
    1. One fixed gas detector
    2. One calibration cap
    3. An instruction manual
    4. A certificate of conformity
    Optional accessoires
    1. 24V DC adapter
    2. Alarm light

    The following points should be noted when using ozone detector

    1. The "Industrial Hygiene Standard" formulated by the Ministry of Health of in 1979 stipulates that the safety standard of ozone is 0.15ppm.
    2. The American standard stipulates that personnel can work for 8 hours at a concentration of 0.1ppm. (The ozone concentration in general forest areas can reach 0.1ppm)
    3. The International Ozone Association stipulates that the professional indoor application of ozone is allowed to work for 10 hours at a concentration of 0.1ppm.
    4. The concentration that causes a certain reaction of personnel is 0.5-1ppm, and the allowable contact time is 1.5 hours. After a long time, worker will feel discomfort such as dry mouth.
    5. The concentration of 1-4ppm will cause coughing, and the allowable contact time is 1 hour.
    6. The concentration of 4-10ppm will cause a strong cough, the allowable contact time is 20 minutes.
    7. The half-life of ozone is 20-50 minutes, and the final decomposition product is oxygen, so there will be no residual contamination to food.

    Contact information:



    Celia Wu

    SHENZHEN YUANTE TECHNOLOGY CO.,LTD(Safegas)

    Mobile/WhatsApp/Wechat: +86 15889417475

    Skype: celia.wu888

    Email: sales04@szyuante.com


    Quality Ozone PPB Level Meter High Precision UK Sensor Ozone Alarm Tester For Safe Clean Room for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen YuanTe Technology Co., Ltd. (Safegas)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)